FAQ

Bushpex Crimp Gas
Is there anything I need to do before using a Manual crimp Tool?

YES – follow all of these important steps below:

  • Ensure that the tool is compatible with BUSHPEX GAS PEX-AL Pipe and BUSHPEX Crimp Gas Fittings
  • Ensure the tool is in good working order
  • Ensure that the jaws align and have no gap when closed
  • Ensure that the jaws are clean, free of defects and debris
  • Refer to the Jointing Procedure in this manual for correct method
If the jaws of the Manual Tool do not align when closed what must I do?

Adjust the jaws and test until the jaws align and have no gap. Follow the process described in the section, “jointing procedures – Tool adjustment”

Is there anything I need to do before using the approved battery crimp Tool?

YES – follow all of these important steps below:

  • Ensure that the tool and jaws are compatible with BUSHPEX
  • GAS PEX-AL Pipe and BUSHPEX Crimp Gas Fittings
  • Read and recognise the instructions contained in the manual • Ensure the correct jaws match the tool, the pipe and the fittings
  • Inspect the tool to ensure it functions properly
  • Inspect the jaws to ensure they’re clean, dry, free of dirt grit and corrosion
If the battery Tool does not fully compress what should I do?
  • Release the trigger and jaws by actuating the retract slide
  • Recharge the battery or replace with charged battery
  • Crimp the joint a second time and check with the crimp gauge
  • Cut off the pipe and fitting if it fails to crimp properly
Do I need to inspect the pipe end prior to crimping?

YES, always inspect the pipe and ensure it is cut square, has been “rounded & deburred”, has no rough edges and the internal and external pipe is undamaged prior to crimping.

Do I need to “round and deburr” the pipe prior to every crimp joint?

YES - this is a requirement for every joint – ensure that the reaming/calibrating tool suits BUSHPEX Gas PEX-AL pipe

Do I need to inspect the crimp fitting prior to every crimp joint?

YES - you should visually inspect each fitting to ensure it is free of any dirt and grit, has both “O” rings intact, the stainless crimp sleeve is properly located and all parts are undamaged – clean/ replace/discard as required.

How can I tell if the pipe has been pushed into the fitting properly?

Inspect the fitting to ensure the pipe is visible through all 4 witness openings

Do I need to check every crimp joint has been compressed properly?

YES - you should check every crimp joint has been compressed properly by testing with the crimp gauge

Is there a procedure to follow when soldering connecting barbs?

YES, ALWAYS:

  • Dismantle the fitting prior to heating and brazing
  • Allow to cool fully before assembly
  • Ensure the yellow plastic retainer rings, two “O” rings and
  • stainless steel sleeve are installed correctly – refer to picture assembly detail on page 9 of this brochure.
What are the requirements for installing the BUSHPEX Crimp Gas system?
  • Must only be installed by a licenced Gas Fitter
  • Must be installed in accordance with AS/NZS 5601
  • Must be installed using the BUSHPEX Crimp Gas PEX-AL Piping system procedures
  • Must be installed using BUSHPEX Gas PEX-AL pipe, BUSHPEX
  • Crimp Gas fittings and tools, licence SMKP 21859
Bushpex Pull On
Can elson BUSHPEX pipe be installed under a slab?

YES – with the following requirements

  • Installation in accordance with AS/NZS 3500.
  • Installed within elson BUSHPEX corrugated sleeve conduit.
  • Must be sleeved when penetrating through a slab.
  • Installed in a single continuous length without fittings.
Can elson BUSHPEX pipe be used for underground cold water service applications?

YES – when installed in accordance with AS/NZS 3500 requirements.

Can elson BUSHPEX pipe and fittings be used to connect solar panels to the storage tank?

NO – Australian Standards do NOT allow PE-X Pipe to be used on the flow or return lines between solar panels and solar storage vessels.

Can braze-on adaptors be installed after crimping elson BUSHPEX Pipe?

NO – Brazing must only ever be done prior to the jointing of the elson BUSHPEX pipe to the fitting. Alternatively use elson PRESS Pull-On fittings from copper to elson BUSHPEX Pull-On.

Is there anything I need to do before using Pull-On Tools?

YES – follow all of these important steps below:

  • Ensure that the all tools are clean, free of dirt, grit, corrosion and fully functional.
  • Ensure the expander head screws entirely onto the expandertool. Incompatible expander tool and heads must never be used!
  • Inspect the expander head for damage, worn or missing parts. If detected isolate, dispose and replace immediately.
  • Refer to the Jointing Procedure in this manual for the correct installation method.
Is there anything I need to do before using the approved battery Pull-On Tool?

YES – follow all of these important steps below:

  • Read and recognise the instructions contained in the manual
  • Inspect the tool to ensure if functions properly
  • Only use the retract slide button release if the battery goes flat or the tool jams. Regular use of this button release puts excessive load on the hydraulics that may affect your warranty.
  • Always keep the tool and jaws clean and dry.
Do I need to inspect the pipe prior to jointing?

YES, always inspect the pipe to ensure it is elson BUSHPEX PE-Xa DN20 Pipe, certificate number WMKA21274. Always ensure the pipe is clean, free of debris and damage free. Any Kinks, cuts or imperfections must be cut out from the installation and disposed of.

Do I need to check every joint has been completed?

YES, it is recommended to incorporate a check system to confirm every sleeve joint has been completed.

Bushpex Crimp On
Can BUSHPEX pipe be installed under a slab?

YES – with the following requirements

  • Installation in accordance with AS/NZS 3500.
  • Installed within BUSHPEX corrugated sleeve conduit.
  • Must be sleeved when penetrating through a slab.
  • Installed in a single continuous length without fittings.
Can BUSHPEX pipe be used for underground cold water service applications?

YES – when installed in accordance with AS/NZS 3500 requirements.

Can BUSHPEX pipe and fittings be used to connect solar panels to the storage tank?

NO – Australian Standards do NOT allow PE-X Pipe to be used on the flow or return lines between solar panels and solar storage vessels.

Can braze-on adaptors be installed after crimping BUSHPEX Pipe?

NO – Brazing must only ever be done prior to the crimping of the BUSHPEX pipe to the fittings with “O” rings, blue plastic retaining ring and Stainless Steel Sleeve removed. Other option? Use BUSHPEX PRESS fittings from copper to BUSHPEX Crimp-On.

Is there anything I need to do before using a Manual Crimp Tool?

YES - follow all of these important steps below:

  • Ensure that the tool is comatible with BUSHPEX PEX pipe and BUSHPEX Crimp-On Fittings.
  • Ensure the tool is good working order.
  • Ensure that the jaws align and have no gap when closed.
  • Ensure that the jaws are clean, free of defects and debris.
  • Refer to Jointing Procedure in this manual for correct method.
If the jaws of the Manual Crimp Tool do not align when closed what must I do?

Adjust the jaws and test until the jaws align and have no gap. Follow the process described in the section, “jointing procedures - Tool adjustment”.

Is there anything I need to do before using the approved battery Crimp Tool?

YES – follow all of these important steps below:

  • Ensure that the tool is compatible with BUSHPEX Pex Pipe and BUSHPEX Crimp-On fittings.
  • Read and recognise the instructions contained in the manual.
  • Ensure the correct jaws match the tool, the pipe and the fittings.
  • Inspect the tool to ensure if functions properly.
  • Inspect the jaws to ensure they’re clean, dry, free of dirt.

If the battery Crimp-On Tool does not fully compress what must I do?
  • Release the trigger and jaws by actuating the retract slide.
  • Recharge the battery or replace with charged battery.
  • Crimp the joint a second time and check with the crimp
  • gauge.
Do I need to inspect the pipe end prior to crimping?

YES, always inspect the pipe and ensure it is cut square, has been “rounded & deburred”, has no rough edges and the internal and external pipe is undamaged prior to crimping.

Do I need to “calibrate” the pipe prior to every crimp joint?

YES – this is a requirement for every joint - ensure that the reaming / calibrating tool suits BUSHPEX Crimp-On Pex Pipe.

Do I need to inspect the crimp fitting prior to every crimp joint?

YES – you should visually inspect each fitting to ensure it is free of any dirt and grit, has both ”0” rings intact, the stainless crimp sleeve is properly located and all parts are undamaged - clean / replace / discard as required.

How can I tell if the pipe has been pushed into the fitting properly?

Inspect the fitting to ensure the pipe is visible through all 4 witness openings.

Do I need to check every crimp joint has been compressed properly?

YES – you should check every crimp joint has been compressed properly by testing with the crimp gauge.